Vicom Systems FC-FC3 Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
CONFIDENTIAL [AK8999A/AW/AD]
MS1600-E-00 2014/05
- 32 -
1.5) S/H Circuit Output Error Adjustment
The S/H circuit output voltage is adjusted to become 0.5*VDD at VOUT pin by using the Output
reference voltage adjustment EEPROM (address: 03h, 08h, data: ELV[8], ELV[7:0]).
1.6) Input gain (G1/G2) setup
Set up G1/G2 gain so that Gain Amp.1/2 output voltages become the ranges (In the case of
VDD = 5V, G1 1600mV, G2 1850mV). The voltage and temperature coefficient which are
used for calculation is as follows.
The offset voltage and the span voltage at 25C take the MAX values of the pressure sensor to be used.
And the offset voltage temperature drift coefficient and the sensitivity temperature drift coefficient take
the MIN values (minus polarity) of the pressure sensor to be used.
Voff25: Offset voltage of the pressure sensor@25C
Vsp25: Span voltage of the pressure sensor @25C
Ktoff: Offset voltage temperature drift coefficient of the pressure sensor (MIN value)
Ktsp: Sensitivity temperature drift coefficient of the pressure sensor (MIN value)
■ In the case of VDD = 5V and temperature = -40 to 105C
Gain Amp.1 output
= G1*(Voff25+Vsp25+ktoff*(-40[C]-25[C])+Vsp25*ktsp*(-40[C]-25[C])) 1600mV
Gain Amp.2 output
= G1*G2*(Vsp25+Vsp25*ktsp*(-40[C]-25[C])) 1850mV
■ In the case of VDD = 3.3V/3.0V and temperature = -40 to 105C
Gain Amp.1 output
= G1*(Voff25+Vsp25+ktoff*(-40[C]-25[C])+Vsp25*ktsp*(-40[C]-25[C])) 750mV/750mV
Gain Amp.2 output
= G1*G2*(Vsp25+Vsp25*ktsp*(-40[C]-25[C])) 990mV/850mV
VOUT
CSCLK
1 4 169
Twr_REG
Hi-z
Level shift
monitor
CSCLK High Time
I2
1
Analog
Output
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare